Friday, 19 October 2012

COAXIAL CABLE TRAINING

COAXIAL CABLE  TRAINING
Introduction
Proper and good quality TV signal cannot be delivered to  the customer without  properly designed and executed RF cabling at customer premises. The rule is  therefore to install RF cabling and equipment first time right so that quality to the customer can be ensured, complaints are minimized and repeated visits to the customer by field teams could be eliminated
NUMBER OF CHANNELS


ANALOG                                75
DIGITAL                                 75
 
HD CHANNELS                   99






 CALCULATING THE IMPEDENCE OF COAXIAL CABLE


Er =Dielectric Constant
                       Air                          =      1                                       Foam              =      1.5  
                      Polyethylene        =     2.3                                    Teflon             =      2.04
BLACK CABLE RG6
INNER  CONDUCTOR      1.02 mm    0.04016 inch
DIELECTRIC                        4.61 mm    0.1815 inch
SHEILD                                  5.2 mm      0.20473 inch
OUTER DIA                          6.7 mm      0.26378 inch


 BLACK CABLE RG 11
INNER CONDUCTOR   1.56mm        0.06142    inch
DIELECTRIC                    7.15mm         0.2815      inch
SHEILD                              7.56mm        0.29764     inch 
OUTER DIA METER       9.72mm        0.36221    inch

Example

 Z=138/√Er *log D/d
Z= 138/ √1.5 *log 4.61/1.02
Z=138/1.22  *log 4.51961
Z=113.12 *06552
Z=74.12